Michelson Interferometer

Δ = 2d · fringe counting · LIGO

Δ = 2d · fringe counting · LIGO

One instrument at two scales:
a lab bench, and LIGO’s 4 km arms.

A beamsplitter sends one laser beam down two arms and brings it back to one screen, where the two beams add as waves. Move one mirror a quarter of a wavelength and its light travels half a wavelength more, there and back: the screen goes from bright to dark. Each half wavelength of travel sends one fringe past the center, so counting fringes measures distance in units of light’s own wavelength, and white light’s fringes mark the place where the arms are equal. LIGO is this instrument with arms 4 km long. A passing gravitational wave stretches one arm and squeezes the other by hundreds of times less than a proton’s width, and the light at its dark output port flickers in a chirp.

In class: a 20-minute route (predict, experiment, explain) runs from the Walkthrough’s first steps through the Sandbox and the Fringe Counter to the Guide, with LIGO as the payoff once the bench makes sense.

Live: the same instrument at two scales. On the bench (top), M2 creeps away from the beamsplitter and new rings are born at the center, one for each half wavelength of travel. At LIGO (below), a passing wave stretches one 4 km arm while it squeezes the other, drawn enormously exaggerated, and the dark port’s meter moves with it.

The round trip doubles the pathA mirror moved by d changes its arm’s light path by 2d, and the center goes through one bright-dark-bright cycle for each half wavelength of travel: N = 2d/λ.
Count fringes to measureCounting N fringes for a known move gives λ = 2d/N; for a known wavelength it gives d = Nλ/2; a gas cell adds 2ℓ(n − 1) to the path.
White light finds zeroA broad spectrum keeps its fringes only within its coherence length, ℓc ≈ λ²/Δλ, so white-light fringes mark equal paths; the interferogram’s transform is the spectrum.
LIGO is a MichelsonA passing wave stretches one arm while squeezing the other by ΔL = hL/2; long arms, a dark output port, arm cavities and high power make a strain of 10⁻²¹ measurable.
Stay in touch