Acid–Base Titration Lab · Guide · glidepathscience.org
GuideAcid–Base Titration Lab
Contents
This Guide explains the chemistry behind every Walkthrough step, Concept Challenge question and Predict round, in the order a textbook would take it. Part 1 prepares the Intro track and Part 2 the Advanced track; each takes about twenty minutes to read. Each section ends with a worked example that is not one of the sim's own problems.
Part 1 · The essentials
Titration and the equivalence point
A titration measures how much of a substance a sample holds by letting it react with a solution of known concentration, the titrant, added a little at a time. In an acid–base titration a buret delivers a strong base such as NaOH into a flask holding an acid, or a strong acid into a base. Each hydroxide ion that arrives takes a proton, quickly and completely: HA + OH⁻ → A⁻ + H₂O. Laboratories still check the strength of vinegar, the acidity of wine and the purity of drugs this way.
The equivalence point is where the titrant added exactly matches the acid in the ratio of the balanced reaction. For an acid with one proton and a base that takes one, the ratio is one to one: the moles of base added, $n_b$, equal the moles of acid in the flask, $n_a$. Moles are concentration times volume, so with $C_a$ and $V_a$ the acid's concentration and volume and $C_b$ the titrant's concentration,
$V_e = \dfrac{C_aV_a}{C_b}$
Read backward, this is why titrations are done: measure $V_e$ with a known $C_b$, and the unknown $C_a = C_bV_e/V_a$ follows. The equation contains no $K_a$ and no pH. A weak acid needs exactly as much base as a strong acid of the same concentration, because every proton it holds is eventually taken; the pH at equivalence is a separate question.
The buret is a long tube marked every 0.10 mL and numbered downward from 0 at the top. Its liquid surface curves into a meniscus: read the scale at the bottom of the curve with your eye level with it, estimating the hundredths between marks. A Class A 50 mL buret is good to about ±0.05 mL, roughly one drop. The volume delivered is the difference of two readings, $V = R_{\text{final}} - R_{\text{initial}}$; taking the final reading alone counts the space between the zero mark and the starting level as if titrant had run out of it, the classic slip.
The equivalence point says nothing yet about the pH on the way there. A strong acid is the simplest case.
A strong acid meets a strong base
A strong acid such as HCl or HNO₃ gives up its proton completely, so the flask holds free H⁺ (really H₃O⁺). The pH is $-\log[\mathrm{H}^+]$, with concentrations in moles per liter, so each pH unit is a factor of ten. Before equivalence the titration is bookkeeping: each OH⁻ removes one H⁺, and what remains is spread through the total volume, acid plus titrant:
$[\mathrm{H}^+] = \dfrac{n_a - n_b}{V_{\text{total}}}$ before $V_e$
Past equivalence the excess hydroxide sets the pH. Water's own equilibrium, H₂O ⇌ H⁺ + OH⁻, ties the two ions together through $K_w = [\mathrm{H}^+][\mathrm{OH}^-]$, and in logarithms, with $\mathrm{pOH} = -\log[\mathrm{OH}^-]$,
$[\mathrm{OH}^-] = \dfrac{n_b - n_a}{V_{\text{total}}}$ $\mathrm{pH} + \mathrm{pOH} = \mathrm{p}K_w$
At 25 °C $\mathrm{p}K_w$ = 13.995; the familiar 14 is rounded. At equivalence only spectator ions such as Na⁺ and NO₃⁻ remain, and the pH is that of pure water, $\tfrac12\mathrm{p}K_w$ = 7.00. Near equivalence the last few drops remove almost all the remaining H⁺, so $[\mathrm{H}^+]$ falls by orders of magnitude and the curve makes its jump. The common slips are dividing by the acid's own volume instead of the total, and reporting the pOH as the pH.
A weak acid behaves differently from the first drop, because most of it never gives up its proton at all.
A weak acid on its own
A weak acid HA, such as acetic, formic or lactic acid, transfers its proton to water only partly, reaching an equilibrium HA ⇌ H⁺ + A⁻ measured by the acid dissociation constant
$K_a = \dfrac{[\mathrm{H}^+][\mathrm{A}^-]}{[\mathrm{HA}]}$ $\mathrm{p}K_a = -\log K_a$
A larger $\mathrm{p}K_a$ means a weaker acid. If $x$ of an acid at concentration $C$ dissociates, $[\mathrm{H}^+] = [\mathrm{A}^-] = x$ and $[\mathrm{HA}] = C - x$, so $K_a = x^2/(C - x)$. When $x$ is only a few percent of $C$, drop it from the denominator:
$[\mathrm{H}^+] \approx \sqrt{K_a C}$ $\mathrm{pH} \approx \tfrac{1}{2}(\mathrm{p}K_a - \log C)$
Check the assumption afterward: a common rule accepts it when $x/C$ is under 5 %, and otherwise solves the quadratic. The usual mistake is to treat the weak acid as strong, $\mathrm{pH} = -\log C$, which can be off by two units or more.
Now add base. The undissociated acid is still there, and it shapes the whole curve.
The buffer region and the halfway point
Hydroxide does not wait for the few free protons; it takes them straight from HA, HA + OH⁻ → A⁻ + H₂O, one for one. After $n_b$ millimoles of base the flask holds $n_a - n_b$ of the acid and $n_b$ of its conjugate base. A solution rich in both is a buffer: added base is used up turning HA into A⁻, and added acid turning A⁻ back, so neither moves the pH much. The $K_a$ expression in logarithms is the Henderson–Hasselbalch equation; since both species share one volume, amounts can replace concentrations:
$\mathrm{pH} = \mathrm{p}K_a + \log\dfrac{n(\mathrm{A}^-)}{n(\mathrm{HA})}$
The pH depends on the ratio of base to acid, not on the amounts, so a buffer can be diluted without changing its pH. While both are plentiful, each drop nudges the ratio only slightly and the curve is nearly flat: the buffer region. It is flattest halfway to equivalence, where $n(\mathrm{A}^-) = n(\mathrm{HA})$ and the log term vanishes:
$\mathrm{pH} \approx \mathrm{p}K_a$ at $V_e/2$
That is how a titration measures $\mathrm{p}K_a$. The equality is approximate because the acid also makes some H⁺ on its own; for a fairly strong or very dilute acid the halfway pH sits measurably above $\mathrm{p}K_a$ (Part 2). The common error is flipping the ratio to acid over base, which puts the pH on the wrong side of $\mathrm{p}K_a$.
At the far end of the buffer region the acid runs out, and the question becomes what the base has left behind.
Equivalence is not neutral
At a weak acid's equivalence point every HA has become A⁻, and the conjugate base of a weak acid is itself a weak base: A⁻ + H₂O ⇌ HA + OH⁻. Its constant follows from the acid's, because the two reactions add up to water's ionization, and the square-root shortcut applies to it as to a weak acid:
$K_b = K_w/K_a$ $[\mathrm{OH}^-] \approx \sqrt{K_b[\mathrm{A}^-]}$
So a weak acid titrated with a strong base reaches equivalence above pH 7, and a weak base titrated with a strong acid below it; only strong with strong, leaving nothing but spectators, is neutral. The reflex that equivalence means pH 7 is the mistake to unlearn; a second is forgetting that $[\mathrm{A}^-]$ has been diluted by the titrant. Past equivalence the excess hydroxide, a far stronger base than A⁻, alone sets the pH through $[\mathrm{OH}^-] = (n_b - n_a)/V_{\text{total}}$, so a weak acid's curve merges with a strong acid's.
An indicator must change color somewhere on this curve; the right one changes inside the jump.
Indicators: the end point and the equivalence point
An acid–base indicator is itself a weak acid, HIn, whose two forms have different colors. By its own Henderson–Hasselbalch equation, $\mathrm{pH} = \mathrm{p}K_{\mathrm{In}} + \log([\mathrm{In}^-]/[\mathrm{HIn}])$, the color shifts over about two pH units around its $\mathrm{p}K_{\mathrm{In}}$. Phenolphthalein turns from colorless to pink between about 8.2 and 10.0, bromothymol blue from yellow to blue between 6.0 and 7.6, methyl red from red to yellow between 4.4 and 6.2, and bromocresol green from yellow to blue between 3.8 and 5.4.
The end point is where you see the color change; the equivalence point is stoichiometry. They coincide within a drop only if the indicator's whole change lies inside the jump. One that changes in the buffer region stops early, because there the pH creeps. To find how early, run Henderson–Hasselbalch backward: at the end-point pH, $n_b/(n_a - n_b) = 10^{\mathrm{pH} - \mathrm{p}K_a}$. Picking the indicator that changes at pH 7 is the usual error; the question is the pH at this titration's equivalence point. One more trap is NaOH that has absorbed CO₂ from the air, turning two OH⁻ into each CO₃²⁻. Titrated to a basic end point, near pH 8 or 9, each carbonate takes back only one proton, so the NaOH acts weaker and the volume comes out large: the carbonate error. Toward pH 5 and below it takes both, and the error all but disappears.
An indicator is judged by eye. A pH meter records the whole curve instead.
Finding the equivalence point with a pH meter
With a meter in the flask, a titration becomes a table of pH against volume. A sharp jump's equivalence point is where the curve is steepest, and between two neighboring readings the steepness is the slope $\Delta\mathrm{pH}/\Delta V$. Find the largest slope and take the middle of its interval as $V_e$; with readings every 0.10 mL near the jump it is good to within a drop, half the reading spacing. Divide by $\Delta V$: the largest $\Delta\mathrm{pH}$ alone is not a slope, and with 0.10 mL steps it is ten times too small. The steepest point and $V_e$ coincide only for a sharp, nearly symmetric jump; Part 2 shows how they part for a very weak or dilute acid, and how noise limits the method.
The same ideas carry over to bases, and to acids with more than one proton.
Weak bases, and acids with more than one proton
A weak base B, such as ammonia or methylamine, titrated with a strong acid gives a mirror image of a weak acid's curve: it starts basic and falls. Its strength is tabulated through the $\mathrm{p}K_a$ of its conjugate acid BH⁺, with $K_b = K_w/K_a$. At the start $[\mathrm{OH}^-] \approx \sqrt{K_bC}$; halfway the pH is close to the $\mathrm{p}K_a$ of BH⁺; at equivalence the flask holds BH⁺, a weak acid, so the pH is below 7 and an indicator that changes on the acid side, such as methyl red, is right. A weak acid titrated with a weak base, such as acetic acid with ammonia, has no sharp jump at all, because both partners buffer near equivalence: 1.5 pH per mL there, against 81 with NaOH.
An acid with several protons, such as phosphoric acid H₃PO₄, gives them up one at a time, each with its own $K_a$ and its own equivalence point. Each shows a jump only if two conditions hold. Neighboring $\mathrm{p}K_a$ values must be about four units apart or more, or their buffer regions merge: citric acid's 3.13, 4.76 and 6.40 give a single jump at the last equivalence point. And the proton must be strong enough beside water itself: near pH 12 much of the added hydroxide simply stays as OH⁻, so a proton with $\mathrm{p}K_a$ near 12 makes no sharp change at its equivalence point. The belief that every proton gives a jump forgets both conditions.
Part 2 · Going further
One equation for every point
Part 1 used a different shortcut in each region. One exact equation covers them all: a solution is electrically neutral. For a weak acid titrated with NaOH this charge balance is $[\mathrm{H}^+] + [\mathrm{Na}^+] = [\mathrm{OH}^-] + [\mathrm{A}^-]$, and in general
$[\mathrm{H}^+] + \sum(\text{cations}) = [\mathrm{OH}^-] + \sum(\text{anions})$
with each ion counted once per charge. The mass balance fixes the acid's total, $C_aV_a/(V_a + V)$, and the sodium, $C_bV/(V_a + V)$; the fractions $\alpha_0 = [\mathrm{H}^+]/([\mathrm{H}^+] + K_a)$ and $\alpha_1 = K_a/([\mathrm{H}^+] + K_a)$ split the total between HA and A⁻; and $[\mathrm{OH}^-] = K_w/[\mathrm{H}^+]$. That leaves one unknown, $[\mathrm{H}^+]$. The Na⁺ is no spectator here: it is how the base enters the equation. Raising $[\mathrm{H}^+]$ raises the positive side and lowers $[\mathrm{OH}^-]$ and $[\mathrm{A}^-]$, so there is exactly one root at every volume, which this sim finds by bisection. Solved instead for the volume, the balance is linear in $V$; with $\Delta = [\mathrm{H}^+] - [\mathrm{OH}^-]$,
$V = V_a\dfrac{C_a\alpha_1 - \Delta}{C_b + \Delta}$
exact at any end point. Henderson–Hasselbalch is not this equation in disguise, but its special case with $\Delta$ negligible beside the buffer's own concentrations.
In the middle of a titration the shortcuts are close. At the edges they are not.
When the shortcuts fail
For a very dilute strong acid, $-\log C$ forgets the H⁺ that water supplies itself. The charge balance $[\mathrm{H}^+] = C + K_w/[\mathrm{H}^+]$ is a quadratic with the positive root
$[\mathrm{H}^+] = (C + \sqrt{C^2 + 4K_w})/2$
(the same in $[\mathrm{OH}^-]$ for a base), always on the correct side of neutral, whereas $-\log C$ makes 10⁻⁸ M acid basic. For a weak acid, $\sqrt{K_aC}$ fails when much of it dissociates, dilute or fairly strong; keep the quadratic,
$x^2/(C - x) = K_a$
The halfway rule fails for the same reason. At $V_e/2$ the sodium is half the acid, but the acid has also dissociated on its own, so $[\mathrm{A}^-] = [\mathrm{Na}^+] + [\mathrm{H}^+] - [\mathrm{OH}^-]$ exceeds half. When $[\mathrm{H}^+]$ is not small beside $[\mathrm{Na}^+]$, the halfway pH sits above $\mathrm{p}K_a$, and quoting $\mathrm{p}K_a$ is the mistake.
Polyprotic acids add more forms to track, and fractions keep them tidy.
Species fractions and amphiprotic points
The species fractions $\alpha_i$ give the share of an acid in each form at a given pH. For a diprotic acid H₂A, with $h = [\mathrm{H}^+]$ and $D = h^2 + K_1h + K_1K_2$, they are $\alpha_0 = h^2/D$, $\alpha_1 = K_1h/D$ and $\alpha_2 = K_1K_2/D$. Neighboring forms are equal where $\mathrm{pH} = \mathrm{p}K_a$, the middle of a buffer region. Between two crossings one form dominates, and there the titration curve jumps: an equivalence point.
At an intermediate equivalence point the dominant form, HA⁻, can both give and take a proton: it is amphiprotic. The charge balance, started from HA⁻ and taking HA⁻ as the main form, gives
$[\mathrm{H}^+] = \sqrt{(K_1K_2C + K_1K_w)/(K_1 + C)}$ $\mathrm{pH} \approx (\mathrm{p}K_{a1} + \mathrm{p}K_{a2})/2$
The shortcut follows when $C \gg K_1$ and $K_1K_2C \gg K_1K_w$; it holds no concentration, so an amphiprotic solution's pH barely changes on dilution. It drifts when $C$ is small, or, at a later point, when $K_w$ is not small beside $K_3C$. Treating the species as only an acid, or only a base, misses by about a pH unit.
A buffer's pH is set by a ratio. How much it can absorb is a separate quantity.
Buffer capacity
Two buffers can share a pH and differ greatly in how much they can absorb. The buffer capacity β is the strong base, in moles per liter, needed per unit rise in pH for a small change, $\beta = dC_b/d\mathrm{pH}$. Differentiating the charge balance gives, for one pair of total concentration $C$,
$\beta = \ln 10\,([\mathrm{H}^+] + [\mathrm{OH}^-] + C\alpha_0\alpha_1)$
Water's two terms matter only near the ends of the scale. The pair's term peaks where $\alpha_0 = \alpha_1 = \tfrac12$, at $\mathrm{pH} = \mathrm{p}K_a$, at $\ln 10 \cdot C/4 \approx 0.576\,C$, and one unit away has fallen to a third: a buffer works best within about a unit of its $\mathrm{p}K_a$, and its capacity grows with concentration while its pH does not. For small changes $\Delta C_b \approx \beta\,\Delta\mathrm{pH}$, base per pH unit as capacitance is charge per volt. The usual slips are taking $C$ as one member's concentration, not the pair's, and forgetting that β is per liter.
Back to meter data, where the rule of the steepest point needs two corrections.
Where the curve is steepest, and noise
The steepest point is the curve's inflection, where $d^2\mathrm{pH}/dV^2 = 0$. For a strong acid it falls at $V_e$, but a weak acid's jump is lopsided, buffered below and not above, so as the acid gets weaker or more dilute (roughly, as $K_aC$ falls) the inflection moves before $V_e$ and its peak in $d\mathrm{pH}/dV$ grows low and broad. At 0.100 M it vanishes once $\mathrm{p}K_a$ passes about 11.2, so a search for the steepest point must allow for none. The steep first milliliter of a weak-acid titration is the buffer forming, not an equivalence point.
Meter readings carry noise. If each has a random error σ, a difference of two has $\sqrt{2}\,\sigma$, since independent errors add in quadrature, and the slope divides that by the spacing:
$\sigma\left(\dfrac{\Delta\mathrm{pH}}{\Delta V}\right) = \dfrac{\sqrt{2}\,\sigma}{\Delta V}$
Halving the spacing doubles the noise; adding the errors directly, as $2\sigma$, overstates it. The second derivative locates the inflection between readings: take the differences of the slopes and interpolate to where they change sign.
One method avoids the noisy jump altogether by using the well-buffered readings.
The Gran plot
Before equivalence, with $n(\mathrm{A}^-) \propto V$ and $n(\mathrm{HA}) \propto V_e - V$, Henderson–Hasselbalch becomes $[\mathrm{H}^+] = K_a(V_e - V)/V$, or $V \cdot 10^{-\mathrm{pH}} = K_a(V_e - V)$: plotted against $V$, a straight line of slope $-K_a$ that meets the volume axis at $V_e$. This Gran plot (Gran, 1952) finds the equivalence point from steady readings well before it. Its textbook form inherits Henderson–Hasselbalch's flaw, forgetting the free H⁺; counting it gives a line in a corrected volume $V'$, exact while OH⁻ is negligible, before $V_e$:
$[\mathrm{H}^+]\,V' = K_a(V_e - V')$ $V' = V + [\mathrm{H}^+](V_a + V)/C_b$
The plot also sorts meter errors. A meter reading a constant δ too high multiplies every $[\mathrm{H}^+]$ by $10^{-\delta}$, scaling the line: $K_a$ changes, the intercept $V_e$ does not. A wrong calibration slope bends the line instead. Taking the slope itself as $\mathrm{p}K_a$, not $-\log$ of its size, is the usual slip.
So far a meter reading has meant $-\log[\mathrm{H}^+]$. Strictly, it is not.
What a pH meter reads
Each ion in solution is surrounded by a cloud of opposite charge that makes it less effective than its concentration suggests. Its effective concentration is its activity, $a = \gamma c$, with γ below 1. A glass electrode responds to the activity of H⁺, and measured pH is defined (IUPAC) as $-\log a(\mathrm{H}^+)$; single-ion activities cannot be measured alone, so any value rests on a convention. The Davies equation estimates γ from the ionic strength $I = \tfrac12\sum c_iz_i^2$:
$\log\gamma = -Az^2(\sqrt{I}/(1 + \sqrt{I}) - 0.3\,I)$, $A = 0.509$
with $A$ for water at 25 °C. It is reasonable to about 0.1 M ionic strength and a rough estimate up to about 0.5 M. Halfway through a titration, with $[\mathrm{A}^-] \approx [\mathrm{HA}]$, a meter reads about $\mathrm{p}K_a + \log\gamma$ and $-\log[\mathrm{H}^+]$ is about $\mathrm{p}K_a + 2\log\gamma$ for a neutral acid HA, both below the tabulated $\mathrm{p}K_a$. For a cation acid such as NH₄⁺ the charge sits on the acid form, and the reading lies above $\mathrm{p}K_a$ instead. Expecting $\mathrm{p}K_a$ itself is the slip.
The electrode's voltage falls by the Nernst slope $s = RT\ln 10/F$ per pH unit, 59.16 mV at 25 °C and growing with absolute temperature: $E = -s(\mathrm{pH} - 7.00)$ about an isopotential point at pH 7.00 and 0 mV. The meter converts $E$ with its calibration slope, so without temperature compensation a sample at another temperature is misread, more so the farther its pH is from 7.
Temperature moves more than the electrode: it moves the equilibria themselves.
Temperature and neutral water
Water's ionization absorbs heat, so warming it ionizes more and $K_w$ grows. A fit to Harned and Robinson's measurements gives, with $T$ in kelvins,
$\mathrm{p}K_w = 4470.99/T - 6.0875 + 0.01706\,T$
which is 13.995 at 25 °C and falls by about 1.9 between 0 and 60 °C. Neutral means $[\mathrm{H}^+] = [\mathrm{OH}^-]$, so
$\mathrm{pH} = \tfrac{1}{2}\,\mathrm{p}K_w(T)$
Neutral water is pH 7 only near 25 °C: warm water is neutral below 7 and cold water above it, and calling warm pure water acidic is the misconception. A strong acid–strong base titration reaches equivalence at that temperature's neutral pH. Each $K_a$ moves too, by the van ’t Hoff equation with $\Delta H^\circ$ taken as constant, $\ln K(T) = \ln K(T_0) - (\Delta H^\circ/R)(1/T - 1/T_0)$: little for carboxylic acids, whose ionization enthalpy is near zero, a lot for amines.
Reference
Common mistakes
- Equivalence means pH 7. It means stoichiometry; the pH depends on what is left in the flask.
- Using the final buret reading as the volume. Subtract the initial reading.
- Dividing by the acid's own volume. Every concentration uses the total volume in the flask.
- Treating a weak acid as strong. −log C assumes complete dissociation; use $\sqrt{K_aC}$ and check it.
- Flipping the Henderson–Hasselbalch ratio. It is base over acid.
- Reporting the pOH as the pH. pH = $\mathrm{p}K_w$ − pOH.
- Choosing the indicator that changes at 7. Choose one whose change lies inside this titration's jump.
- Expecting a jump for every proton. Close $\mathrm{p}K_a$ values merge, and a proton near $\mathrm{p}K_a$ 12 gives none.
- Taking the steepest point as $V_e$ for a very weak acid. It comes early, or not at all.
- Calling warm neutral water acidic. Neutral is $\tfrac12\mathrm{p}K_w$ at the water's own temperature.
Equation sheet
| Part 1 | |
|---|---|
| equivalence | $V_e = C_a V_a / C_b$: moles of base ($n_b$) = moles of acid ($n_a$) |
| buret | $C_a = C_b(R_{\text{final}} - R_{\text{initial}})/V_a$ |
| strong acid | $[\mathrm{H}^+] = (n_a - n_b)/V_{\text{total}}$ |
| weak acid alone | $[\mathrm{H}^+] \approx \sqrt{K_a C}$ |
| buffer | $\mathrm{pH} = \mathrm{p}K_a + \log(n(\mathrm{A}^-)/n(\mathrm{HA}))$ |
| at $V_e$ | $[\mathrm{OH}^-] \approx \sqrt{K_b[\mathrm{A}^-]}$, $K_b = K_w/K_a$ |
| past $V_e$ | $[\mathrm{OH}^-] = (n_b - n_a)/V_{\text{total}}$ |
| water | $\mathrm{pH} + \mathrm{pOH} = \mathrm{p}K_w$ = 13.995 at 25 °C |
| Part 2 | |
|---|---|
| charge balance | $[\mathrm{H}^+] + \sum(\text{cations}) = [\mathrm{OH}^-] + \sum(\text{anions})$ |
| backwards | $V = V_a(C_a\alpha_1 - \Delta)/(C_b + \Delta)$, $\Delta = [\mathrm{H}^+] - [\mathrm{OH}^-]$ |
| dilute strong acid | $[\mathrm{H}^+] = (C + \sqrt{C^2 + 4K_w})/2$ |
| weak acid, exact | $x^2/(C - x) = K_a$ |
| amphiprotic | $[\mathrm{H}^+] = \sqrt{(K_1K_2C + K_1K_w)/(K_1 + C)}$, $\mathrm{pH} \approx (\mathrm{p}K_{a1} + \mathrm{p}K_{a2})/2$ |
| capacity | $\beta = \ln 10\,([\mathrm{H}^+] + [\mathrm{OH}^-] + C\alpha_0\alpha_1)$ |
| Gran (exact) | $[\mathrm{H}^+]\,V' = K_a(V_e - V')$, $V' = V + [\mathrm{H}^+](V_a + V)/C_b$ |
| Davies | $\log\gamma = -Az^2(\sqrt{I}/(1 + \sqrt{I}) - 0.3\,I)$, $A = 0.509$ |
| noise | $\sigma(\Delta\mathrm{pH}/\Delta V) = \sqrt{2}\,\sigma/\Delta V$ |
| neutral | $\mathrm{pH} = \tfrac{1}{2}\,\mathrm{p}K_w(T)$ |
Symbols: $C_a$, $V_a$ the acid's concentration (M) and volume (mL) · $C_b$ the titrant's concentration · $V$ titrant added, $V_e$ at equivalence · $n_a$, $n_b$ amounts (mmol) · $R$ buret readings · $K_a$, $K_b$, $K_w$ acid, base and water constants, $\mathrm{p}K = -\log K$ · $\alpha_i$ species fractions · β buffer capacity (M per pH) · γ activity coefficient, $I$ ionic strength (M), $z$ ion charge · $s = RT\ln 10/F$ the electrode slope. 1 M = 1 mol/L = 1,000 mol/m³; 1 mL = 10⁻⁶ m³.
Further reading
OpenStax, Chemistry 2e, chapter 14, “Acid–Base Equilibria” (§14.5 Polyprotic Acids, §14.6 Buffers, §14.7 Acid–Base Titrations), whose order and notation Part 1 follows; D. Harvey, Analytical Chemistry 2.1, an open textbook, chapters 6 and 9, for the charge balance, buffer capacity and Gran plots; R. de Levie, Aqueous Acid–Base Equilibria and Titrations (Oxford, 1999), for the curve written as an explicit function of pH. The Field Manual lists every data source.
Acid–Base Titration Lab v1.6 · © 2026 Dr. David Meier · CC BY-NC-SA 4.0 · glidepathscience.org